1.
Res Sq ; 2021 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-34013243

RESUMO

Severe COVID-19 is associated with unprecedented thromboembolic complications. We found that hospitalized COVID-19 patients develop immunoglobulin Gs (IgGs) that recognize a complex consisting of platelet factor 4 and heparin similar to those developed in heparin-induced thrombocytopenia and thrombosis (HIT), however, independent of heparin exposure. These antibodies activate platelets in the presence of TLR9 stimuli, stimuli that are prominent in COVID-19. Strikingly, 4 out of 42 antibodies cloned from IgG1+ RBD-binding B cells could activate platelets. These antibodies possessed, in the heavy-chain complementarity-determining region 3, an RKH or Y5 motif that we recently described among platelet-activating antibodies cloned from HIT patients. RKH and Y5 motifs were prevalent among published RBD-specific antibodies, and 3 out of 6 such antibodies tested could activate platelets. Features of platelet activation by these antibodies resemble those by pathogenic HIT antibodies. B cells with an RKH or Y5 motif were robustly expanded in COVID-19 patients. Our study demonstrates that SARS-CoV-2 infection drives the development of a subset of RBD-specific antibodies that can activate platelets and have activation properties and structural features similar to those of the pathogenic HIT antibodies.

2.
Artif Organs ; 45(1): 22-28, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32737900

RESUMO

Our objective was to assess the effect of nitric oxide added to the sweep gas of the oxygenator during cardiopulmonary bypass (CPB) in infants on platelet count, platelet function, clinical outcomes, and safety. A randomized, double-blinded, placebo-controlled clinical trial in infants less than a year of age undergoing cardiac surgery requiring CPB was undertaken. Nitric oxide at a dose of 20 ppm was added to the sweep gas in the treatment group. Blood was collected at baseline and prior to separation from CPB to measure platelet count and function as determined by responsiveness to specific agonists. Clinical outcomes were observed through hospital discharge. Methemoglobin levels were measured preoperatively, at the conclusion of CPB, and upon admission to the ICU. Forty patients consented and were randomized in the trial. Eighteen patients were randomized to the treatment group and 22 were included in the placebo group. The groups were similar in terms of age, weight, gender, and surgical complexity. No significant differences were found in measures of platelet count, platelet response to agonist, or clinical outcomes. Patients in the treatment group had higher methemoglobin levels after receiving nitric oxide, but no levels approached toxicity (maximum 2.4%). Nitric oxide added to the sweep gas of the oxygenator during CPB in infants did not have an appreciable effect on the preservation of platelet count, platelet responsiveness to agonist, or clinical outcomes. Methemoglobin levels were increased after receiving nitric oxide but were far below a toxic level of 15%.


Assuntos
Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Ponte Cardiopulmonar/efeitos adversos , Óxido Nítrico/administração & dosagem , Oxigenadores/efeitos adversos , Agregação Plaquetária/efeitos dos fármacos , Procedimentos Cirúrgicos Cardíacos/instrumentação , Procedimentos Cirúrgicos Cardíacos/métodos , Ponte Cardiopulmonar/instrumentação , Ponte Cardiopulmonar/métodos , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Metemoglobina/análise , Projetos Piloto , Testes de Função Plaquetária , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...